Energie · Gebäude · Umwelt (EGU)
Refine
Year
Publication Type
- Lecture (610)
- Article (308)
- Part of a Book (89)
- Conference Proceeding (80)
- Book (36)
- Contribution to a Periodical (25)
- Report (23)
- Participation in a Norm (DIN, RFC etc.) (20)
- Other (4)
- Sound (4)
Language
- German (931)
- English (228)
- Multiple languages (49)
- Spanish (3)
Keywords
- Überflutung (28)
- Überflutungsvorsorge (19)
- Hochwasser (18)
- Starkregen (18)
- Klimawandel (16)
- Trinkwasserinstallation (11)
- Urbanes Grün (11)
- Bewässerung (9)
- Baumrigole (7)
- Trinkwasserhygiene (7)
Blockheizkraftwerke
(1992)
Blockheizkraftwerke
(1995)
For the increasingly important storage of renewably generated electricity, this review explains the construction of a surface and underground pumped storage
power plant. The problems for the construction of an underground pumped storage power plant are further listed. These are geological, environmental and
economic problems as well as a low acceptance by the population. The geological problems are concerns about leaching of minerals and heavy metals as well as the statics of the cavities. Mining companies in Germany are obligated to renaturalize the landscape areas again, which could be realised by a lake. Furthermore, care must be taken to ensure that the mine water does not come into contact with the groundwater. According to a survey by RISP on the subsequent use of the mine areas for an underground pumped
storage power plant, the acceptance of the population is over 70 percent. The economic consideration concludes that the arbitrage profit for a difference between off-peak and peak of 10 €/MWh is about 2.7 M€/a and for 100 €/MWh about 27.3 M€/a. With investment costs of about 630 M€, despite the assumption of 100 €/MWh, more than 20 years are needed for an underground pumped storage power plant to be amortized. The acceptance could be increased by creating a lake as a recreation area as well as being used as an upper storage reservoir. Thus, the cost of renaturation decrease when combined with the creation of the storage basin. The problem of ground conditions can be solved by creating new cavities by means of tunnel boring at an inclination. For static safety as well as against leaching of minerals and heavy metals, the cavity walls can be sealed with reinforced concrete. The technology of underground pumped storage power plants can be used for better utilisation of renewable energies. This is especially in flat and densely populated regions a possibility to store energy, because the main part of the power plant is underground.
Childhood social position and associations between environmental exposures and health outcomes
(2008)
CO2-Emissionen im Münsterland; Gewerkschaften gestalten den Wandel, NRW DGB, Münster, Januar 2020
(2020)
This document presents a comparative analysis of
horizontal and vertical small wind turbines for urban
areas in three power classes up to 10 kW in different
categories. The main objective was to conduct a market
analysis to assess the marketability of these wind
energy systems. The aim was to make it easier for
potential customers to make a decision. However, due
to the limited availability of data, the project encountered
considerable difficulties. As a result, the study
became a comparative assessment, which led to results
that may not be readily transferable to urban environments,
slightly missing the original objective of the
study. The results underline the difficulties associated
with conducting a comprehensive market analysis in
this sector and highlight the need for an independent
series of tests under specific conditions. The paper
concludes with a plea for future research efforts to
adapt data collection methods to urban conditions in
order to improve the relevance and applicability of
such studies in practice.
A novel approach for ventilation systems is a periodically varying supply air flow rate, the so-called unsteady mode of operation. So far, useful effects of this unsteady operating mode have been observed, but the effect mechanisms are still unknown. In this manuscript, simulations using the recently proposed k-ω-ζ - f model implemented in a sensitized RANS computational framework for a cuboid room with swirl diffusers are compared and validated with PIV measurements.
Control strategies for optimisation of urban wastewater system based on precipitation forecast
(2001)
Originally this article was supposed to be a comparison between the technological differences of bottom-fixed offshore wind turbines (BOWT) and floating offshore wind turbines (FOWT). However, several authors already contributed to this topic and came to the conclusion that the higher levelized costs of energy (LCOE) prevent FOWTs from successfully entering the energy market. Multiple sources seem to agree on this conclusion but often do not provide the reader with further information regarding the LCOE. This is the reason why this article understands itself as an in depth cost comparison between BOWTs and FOWTs. For this purpose, individual LCOE are calculated for the upcoming FOWT technologies such as spar-buoy (SPAR), tension-leg platform (TLP) and semi-submersible platform (semi-sub) as well as conventional BOWTs using the wind turbines hours of full utilization (HOFU). The resulting functions are visualized graphically in order to determine break-even points between BOWTs and FOWTs. Finally, a sensitivity analysis is carried out to determine the influence of the weighted average costs of capital (WACC).
When simulating and optimizing urban energy systems, the focus is usually on minimizing financial costs or greenhouse gas (GHG) emissions. As energy systems transition towards a growing share of renewable energy sources and technological complexity, environmental impacts that affect more than just GHG emissions, such as resource extractions, water and land use impacts or impacts on human health, are becoming increasingly relevant.
To address this gap, this thesis introduces an automated coupling procedure for energy system modeling (ESM) and life cycle assessment (LCA). The implementation includes general recommendations and a practical coupling of the Open Energy Modelling Framework (oemof) based Spreadsheet Energy System Model Generator (SESMG) with a suitable LCA software.
The LCA procedure involves goal and scope definition, inventory analysis, impact assessment, and interpretation. To adapt these steps to different energy system models, the LCA should be attributional, process-based and territorial. Further, the openLCA software by Green-Delta serves as a suitable soft-linking tool. The main challenge of the coupling procedure is the inventory analysis. Data collection faces limitations, reasoned by the commercialization and high maintenance efforts in open-source databases. After evaluating free databases, the Prozessorientierte Basisdaten für Umweltmanagement-Instrumente (ProBas) database of the Umweltbundesamt emerged as the most suitable choice for the coupling. However, also this database lacks traceability of datasets or compatibility with a comprehensive impact assessment.
A generalized framework for the LCA application of energy systems was developed. The framework is based on an ex-post LCA assessment that considers the combination of the two approaches within every step of the procedure. Main considerations of this framework include automatic calculations of the inventory analysis and the impact assessment for different energy technologies, as well as calculations summed up for all technologies of energy system scenarios. Further, technology mapping and data harmonization are essential considerations for the automatic coupling and double counting of impacts needs to be avoided.
Subsequently, the framework is realized with the adaption of the SESMG. Its database-independent realization allows compatibility with different databases in openLCA. For the selected ProBas database, the tool can be used with different available energy technologies. The use of unit processes is encouraged for data harmonization. Result interpretation of the LCA (in general or with the SESMG) should not solely focus on the absolute values of the impact categories, but rather on the comparative strengths among scenarios and technologies.
The successful application to a reference single-family building using the ProBas database revealed varied environmental impacts, in relation with a higher reduction in GHG emissions, with an increase of 11 % in terrestrial acidification impacts in the emission-optimized scenario. These findings emphasize a more comprehensive perspective on environmental impacts and provide a valuable validation of the developed methodology.
Future research should include the improvement of data harmonization, the inclusion of more datasets for a more customized analysis of energy systems and more applications. The coupled approach offers a promising avenue for gaining deeper insights into optimizing urban energy systems.
Different model structures were compared to simulate the characteristic process variables of the anaerobic digestion of maize, sugar beet and grain silage. Depending on the type and number of the required components, it can be shown that in comparison to the complex Anaerobic Digestion Model No. 1 (ADM1) different simplified model structures can describe the gas production rate, ammonia nitrogen and acetate concentration or pH value equally well. Since the reduction of the predominantly fast kinetics of the methanogenesis, acetogenesis or acidogenesis will only have little effect on the simulation of the specific gas production, it can be proven that the hydrolysis is the rate-limiting step during the uninhibited anaerobic digestion of complex particulate substrates. However, the stoichiometric comparison reveals that the model protein gelatine is not suitable for a representative characterization of agricultural energy crops.
This review is about where and which tidal power systems are currently deployed. It starts with an insight into the variety of different tidal power systems. With the help of a list from the European Marine Energy Center about currently used systems for tidal power plants, it quickly becomes apparent that two systems stand out. These are the vertical and horizontal turbines. The latter are particularly common, as they are used for both tidal stream and tidal range power plants. Determining the regions with high potential for tidal power is not always easy due to the many influencing factors. Influencing factors are, for example form and conditions of the seabed, topographical features of the coast or currents in the sea [1]. Therefore, each region must be considered separately. n this paper the focus is on the UK, the literature shows that the coastal regions around the UK provide about 50 TWh/year of the European tidal power potential. This is due to the location between the oceans and the geological conditions, which act as a channel for the tides. The two areas with high potential where planning
and construction of tidal power plants is currently underway are in the north of Scotland and in the southwest of England in the Bristol Channel.
Das gescheiterte Liebesleben von Fischen. Münsters Wissenschaftsfestival Schlauraum Grund:Wasser.
(2022)
Flexible biogas production can enable demand-oriented energy supply without the need for expensive gas storage expansions, but poses challenges to the stability of the anaerobic digestion (AD) process. In this work, biogas production of laboratory-scale AD of maize silage and sugar beets was optimized to cover the residual load of an electricity self-sufficient community using a simple process model based on first-order kinetics. Experiments show a good agreement between biogas demand, predicted, and measured biogas production. By optimizing biogas conversion schedules based on the measured gas production, a gas storage capacity of 7-8 h was identified for maximum flexibility, which corresponds to typical gas storage sizes at industrial biogas plants in Germany. Various stability indicators were continuously monitored and proved resilient process conditions. These results demonstrate that demand-oriented biogas production using model predictive control is a promising approach to enable existing biogas plants to provide balancing energy.
Der Spreadsheet Energy System Model Generator (SESMG) ist ein Werkzeug zur Modellierung und Optimierung von (urbanen) Energiesystemen. Der SESMG hat eine browserbasierte grafische Benutzeroberfläche, eine tabellenbasierte Dateneingabe und eine ausführliche Dokumentation, was einen einfachen Einstieg ermöglicht. Zudem erfordern die Installation und Anwendung keine Programmierkenntnisse. Im SESMG sind verschiedene Modellierungsmethoden implementiert, wie z. B. die Anwendung des Multi-Energie-System-Ansatzes, die multikriteriale Optimierung, modellbasierte Methoden zur Reduktion des Rechenaufwands sowie die automatisierte Erstellung von räumlich hoch aufgelösten Energiesystemmodellen. Somit können urbane Energiesysteme mithilfe des SESMGs mit vergleichsweise geringem Aufwand, aber unter Berücksichtigung einer Vielzahl von Parametern und Randbedingungen, modelliert und optimiert werden.
The development of compact treatment devices with high removal efficiencies and low space requirements is a key objective of urban stormwater
treatment. Thus, many devices utilize a combination of sedimentation and upward flow filtration in a single system. This study, for the
first time, evaluates the flow field inside a combined filter-lamella separator via computational fluid dynamics. Herein, three objectives
are investigated: (i) the flow field for different structural configurations, (ii) the distribution of particulate matter along the filter bed and
(iii) the dynamic clogging in discrete filter zones, which is addressed by a clogging model derived from literature data. The results indicate
that a direct combination of a filtration stage with a lamella separator promotes a uniform flow distribution. The distribution of particulate
matter along the filter bed varies with configuration and particle size. Clogging, induced by particles in the spectrum ,63 μm, creates
gradients of hydraulic conductivity along the filter bed. After treating about half of Germany’s annual runoff-efficient precipitation at a rainfall
intensity of 5 L/(s·ha), the filtration rates increase in the front of the filter bed by þ10%. Thus, long-term operating behavior is sensitive to
efficient filter utilization in compact treatment devices.