Refine
Publication Type
- Article (10)
- Conference Proceeding (6)
- Other (4)
- Report (2)
- Working Paper (2)
- Contribution to a Periodical (1)
Keywords
- PIV (5)
- Lüftungstechnik (3)
- energy system model (3)
- energy system modeling (3)
- instationäre Lüftung (3)
- modeling tools (2)
- unsteady ventilation (2)
- urban energy system (2)
- CFD (1)
- Dynamic airflow (1)
Faculty
Der Spreadsheet Energy System Model Generator (SESMG) ist ein Werkzeug zur Modellierung und Optimierung von (urbanen) Energiesystemen. Der SESMG hat eine browserbasierte grafische Benutzeroberfläche, eine tabellenbasierte Dateneingabe und eine ausführliche Dokumentation, was einen einfachen Einstieg ermöglicht. Zudem erfordern die Installation und Anwendung keine Programmierkenntnisse. Im SESMG sind verschiedene Modellierungsmethoden implementiert, wie z. B. die Anwendung des Multi-Energie-System-Ansatzes, die multikriteriale Optimierung, modellbasierte Methoden zur Reduktion des Rechenaufwands sowie die automatisierte Erstellung von räumlich hoch aufgelösten Energiesystemmodellen. Somit können urbane Energiesysteme mithilfe des SESMGs mit vergleichsweise geringem Aufwand, aber unter Berücksichtigung einer Vielzahl von Parametern und Randbedingungen, modelliert und optimiert werden.
A novel approach for ventilation systems is a periodically varying supply air flow rate, the so-called unsteady mode of operation. So far, useful effects of this unsteady operating mode have been observed, but the effect mechanisms are still unknown. In this manuscript, simulations using the recently proposed k-ω-ζ - f model implemented in a sensitized RANS computational framework for a cuboid room with swirl diffusers are compared and validated with PIV measurements.
The effects of different unsteady ventilation strategies on flow-structures in a room are investigated and compared to steady ventilation with the same mean exchange rate. For this, whole-field optical flow measurements were executed by means of a particle image velocimetry system (PIV) in a Reynolds-scaled room model in water. In a first series of experiments, sinusoidal varied supply flows with different frequencies were analysed; two equally supplied simple nozzles in the ceiling were used as inlets. The setup was validated by comparing jet velocities with literature values.
Typically, room airflows are investigated with punctual measurement techniques (e.g.
anemometers), which have an impact on the flow field, or with smoke gas experiments. By using PIV, the flow can be analysed without any influence of sensors or stands/traverses and whole-field measurement data with high spatial resolution and detailed information on the flow field can be collected.
Local and time-averaged velocities and standard deviations were calculated for all scenarios. Unsteady conditions were created by a sinusoidal variation of the supply flow rate with frequencies between 0.025 1/s and 0.050 1/s, an offset of about 1.1 m3/h and an amplitude of about ±1.0 m3/h, which leads to a mean exchange rate of 3.5 1/h. Although averaged velocity fields only show slight differences between steady and unsteady conditions, single pictures vary widely. First effects of unsteady ventilation on flow structures can be recognized. Steady structures are destroyed, and velocities change rapidly.
The inlets will be changed to small-scale ceiling-diffusors in future experiments to create more realistic room ventilation conditions. Other types of unsteady supply flows will be implemented, and parameters will be varied. The results of the PIV-measurements can be used to validate CFD simulations and to derive dimensioning rules and application recommendations.
Mit wenigen Ausnahmen wird im elektrischen Versorgungssystem die Pumpspeichertechnik zur Pufferung größerer Abweichungen zwischen momentanem Stromverbrauch und -erzeugung und zur zeitlichen Verschiebung von Lasten eingesetzt. Erste großtechnische Anlagen wurden bereits Ende der zwanziger Jahre des letzten Jahrhunderts in Deutschland gebaut, um die Auslastung thermischer Kraftwerke gleichmäßiger zu ermöglichen. Pumpspeicherwerke bieten sich somit als Referenztechnologie an, mit der sich neue Entwicklungen messen müssen. Ein Überblick.
Unsteady ventilation is being discussed to improve indoor air quality and comfort by simultaneously reducing the energy consumption. But until now, neither any standard system has been established nor are there any design parameters and clear specifications in standards. One reason for this lack of standardisation might be the ver-satile approaches for creating unsteady room airflows: sinusoidal variations, intermittent flow rates, and simu-lated natural wind or temperature variations in forced convection and the use of chaotic structures in free convection. Thus, this article gives an overview of systems available in Germany/Europe, international research and unresolved issues. It allows a clear focus for future investigations to be developed so that unsteady venti-lation concepts will be successfully utilised in practice. Experiments showed positive effects on indoor air quality (IAQ), comfort and energy consumption. However, two main questions have not been answered, yet: what are the fluid mechanical reasons for the observed effects and what are the best parameters to create unsteady room airflows?
About 75% of the world's energy consumption takes place in cities. Although their large energy consumption attracts a large number of research projects, only a small fraction of them deal with approaches to model energy systems of city districts. These are particularly complex due to the existence of multiple energy sectors (multi-energy systems, MES), different consumption sectors (mixed-use), and different stakeholders who have many different interests.
This contribution is a review of the characteristics of energy system models and existing modeling tools. It evaluates current studies and identifies typical characteristics of models designed to optimize MES in mixed-use districts. These models operate at a temporal resolution of at least 1 h, follow either bottom-up or hybrid analytical approaches and make use of mixed-integer programming, linear or dynamic.
These characteristics were then used to analyze minimum requirements for existing modeling tools. Thirteen of 145 tools included in the study turned out to be suitable for optimizing MES in mixed-use districts. Other tools where either created for other fields of application (12), do not include any methodology of optimization (39), are not suitable to cover city districts as a geographical domain (44), do not include enough energy or demand sectors (20), or operate at a too coarse temporal resolution (17). If additional requirements are imposed, e.g. the applicability of non-financial assessment criteria and open source availability, only two tools remain.
Overall it can be stated that there are very few modeling tools suitable for the optimization of MES in mixed-use districts.
Rund 75 % des weltweiten Energieverbrauchs findet innerhalb urbaner Energiesysteme statt. Solche Systeme beinhalten mehrere Energiesektoren (Elektrizität, Wärme, Kälte, …), Verbrauchssektoren (Wohnen, Gewerbe, Industrie, Landwirtschaft, Mobilität, …) und Interessensgruppen und sind deshalb besonders komplex. Durch den Einsatz von Methoden der Energiesystemmodellierung können diese komplexen Systeme simuliert, analysiert und optimiert werden. Mit Simulationsmodellen können Kosten, Emissionen und verschiedene andere Systemparameter prognostiziert werden. Mithilfe von Optimierungsalgorithmen können Technologien miteinander verglichen, Anlagen dimensioniert und Betriebsweisen optimiert werden. Die Erkenntnisse aus Energiesystemmodellen können zur Einhaltung verschiedener politischer und sozialer Ziele, wie beispielsweise die Reduktion von Treibhausgasemissionen, der Bedarf nach kostengünstiger Energieversorgung oder auch die Stärkung der regionalen Wirtschaft, beitragen.
Im Projekt R2Q werden Ansätze der Energiesystemmodellierung für den Einsatz in der Planung urbaner Energiesysteme aufgearbeitet, angepasst und für städteplanerische Prozesse verfügbar gemacht. In ersten Modelldurchläufen für ein Testgebiet in Herne konnte durch die Kombination verschiedener Technologien eine rechnerische Minimierung der monetären Kosten um 19 % bei gleichzeitiger Reduktion der CO2-Emissionen um 36 % ermittelt werden. Durch ein emissionsoptimiertes Szenario können die CO2-Emissionen um 47 % reduziert werden, was jedoch mit einer Steigerung der Kosten um 29 % einhergeht.