Refine
Year
- 2018 (49)
- 2014 (44)
- 2015 (44)
- 2017 (42)
- 2019 (39)
- 2016 (37)
- 2011 (29)
- 2010 (24)
- 2012 (23)
- 2021 (21)
- 2020 (20)
- 2005 (16)
- 2009 (14)
- 2022 (14)
- 2003 (13)
- 2006 (13)
- 2013 (10)
- 2002 (9)
- 2000 (8)
- 2001 (8)
- 2004 (8)
- 2007 (6)
- 2023 (6)
- 1994 (3)
- 2008 (3)
- 2024 (3)
- 1987 (2)
- 1993 (2)
- 1997 (2)
- 1999 (2)
- 1984 (1)
- 1989 (1)
- 1991 (1)
- 1995 (1)
Publication Type
- Article (257)
- Lecture (87)
- Conference Proceeding (86)
- Part of a Book (84)
- Book (2)
- Contribution to a Periodical (2)
Language
- English (518) (remove)
Keywords
Faculty
- Physikingenieurwesen (PHY) (518) (remove)
26.3.-30.3.: DPG spring meeting Berlin: Instability of a repulsive Bose gas near the BEC transition
(2012)
26.3.-30.3.: DPG spring meeting Berlin: Modeling the morphogenesis of brine channels in sea ice
(2012)
A detailed look beneath the surface: Evidence of a surface reconstruction beneath a capping layer
(2016)
Astronomy is driven by the quest for higher sensitivity and improved angular resolution in order to detect fainter or smaller objects. The far-infrared to submillimeter domain is a unique probe of the cold and obscured Universe, harboring for instance the precious signatures of key elements such as water. Space observations are mandatory given the blocking effect of our atmosphere. However the methods we have relied on so far to develop increasingly larger telescopes are now reaching a hard limit, with the JWST illustrating this in more than one way (e.g. it will be launched by one of the most powerful rocket, it requires the largest existing facility on Earth to be qualified). With the Thinned Aperture Light Collector (TALC) project, a concept of a deployable 20 m annular telescope, we propose to break out of this deadlock by developing novel technologies for space telescopes, which are disruptive in three aspects: • An innovative deployable mirror whose topology, based on stacking rather than folding, leads to an optimum ratio of collecting area over volume, and creates a telescope with an eight times larger collecting area and three times higher angular resolution compared to JWST from the same pre-deployed volume; • An ultra-light weight segmented primary mirror, based on electrodeposited Nickel, Composite and Honeycomb stacks, built with a replica process to control costs and mitigate the industrial risks; • An active optics control layer based on piezo-electric layers incorporated into the mirror rear shell allowing control of the shape by internal stress rather than by reaction on a structure. We present in this paper the roadmap we have built to bring these three disruptive technologies to technology readiness level 3. We will achieve this goal through design and realization of representative elements: segments of mirrors for optical quality verification, active optics implemented on representative mirror stacks to characterize the shape correction capabilities, and mechanical models for validation of the deployment concept. Accompanying these developments, a strong system activity will ensure that the ultimate goal of having an integrated system can be met, especially in terms of (a) scalability toward a larger structure, and (b) verification philosophy.
A New Combined Optical and Robotic Testing System to Evaluate Multisegmental Spinal Kinematics
(2010)
The mechanical set up of a novel scanning reflection X-ray microscope is presented. It is based on zone plate optics optimized for reflection mode in the EUV spectral range. The microscope can operate at synchrotron radiation beamlines as well as at laboratory-based plasma light sources. In contrast to established X-ray transmission microscopes that use thin foil samples the new microscope design presented here allows the investigation of any type of bulk materials. Importantly, this permits the investigation of magnetic materials by employing experimental techniques based on the X-ray magnetic circular dichroism (XMCD), the X-ray linear magnetic dichroism or the transversal magneto-optical Kerr effect (T-MOKE). The reliable functionality of the new microscope design has been demonstrated by T-MOKE microscopy spectra of Fe/Cr-wedge/Fe trilayer samples. The spectra were recorded at various photon energies across the Fe 3p edge revealing the orientation of magnetic domains in the sample.
In this paper a novel concept of ablation cell for laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is presented. Suppression of the turbulence in the flush gas flow in the ablation region reduces the wash-out time of the ablation cell considerably. An ablation chamber which enables ICP-MS pulse duration down to several ten milliseconds has been designed. Dependence of the ICP-MS peak amplitude, width, and shape on the gas flow parameters is studied experimentally for aerosol ablated under laminar and turbulent conditions. Experiments demonstrate that the ICP-MS peak becomes sharper and the amplitude of the signal grows as the turbulence in the ablation cell is suppressed. Furthermore, the possibility of the LA-ICP-MS analysis with a sampling rate of more than 10 Hz has been demonstrated. Express in-depth profiling in the new ablation cell is demonstrated on examples of an Al -Zn multilayer structure and an industrial Mg -Zn coating.
Image-sharpness metrics can be used to optimize optical systems and to control wavefront sensorless adaptive optics systems. We show that for an aberrated system, the numerical value of an image-sharpness metric can be improved by adding specific aberrations. The optimum amplitudes of the additional aberrations depend on the power spectral density of the spatial frequencies of the object.
Adaption of the NDIR-technology to 13CO2-breath tests under increased inspiratory O2 concentrations
(2009)
Active optics is an enabling technology for future large space telescopes. Image-based wavefront control uses an image-sharpness metric to evaluate the optical performance. A control algorithm iteratively adapts a corrective element to maximize this metric, without reconstructing the wavefront. We numerically study a sharpness metric in the space of Zernike modes, and reveal that for large aberrations the Zernike modes are not orthogonal with respect to this metric. The findings are experimentally verified by using a unimorph deformable mirror as
corrective element. We discuss the implications for the correction process and the design of control algorithms.
Analytical features of particle counting sensor based on plasmon assisted microscopy of nano objects
(2011)
Anomaly transport
(2019)
Laser shock peening is a new and important surface treatment technique that can enhance the mechanical properties of metal materials. Normally, the nanosecond laser with pulse-width between 5 ns and 20 ns is used to induce a high-pressure shock wave that can generate plastic deformation in the top layer of metals. The femtosecond laser shock peening in the air has been studied recently, which can induce higher pressure shock wave than that of traditional nanosecond laser shock peening in a very short time. The NiTi alloy is processed by femtosecond laser shock peening, then a nanoindentation device is used to measure its surface hardness and residual stress. The hardness results of NiTi alloy before and after treatment show that the femtosecond laser shock peening can increase the hardness of NiTi alloy, which also shows that the femtosecond laser can be used to perform laser shock peening on NiTi alloy without coating.
The mechanisms of femtosecond laser-induced transient melting and atomic mixing in a target composed of a 30 nm Au film deposited on a bulk Cu substrate are investigated in a series of atomistic simulations. The relative strength and the electron temperature dependence of the electron-phonon coupling of the metals composing the layered target are identified as major factors affecting the initial energy redistribution and the location of the region(s) undergoing transient melting and resolidification. The higher strength of the electron-phonon coupling in Cu, as compared to Au, results in a preferential sub-surface heating and melting of the Cu substrate, while the overlaying Au film largely retains its original crystalline structure. The large difference in the atomic mobility in the transiently melted and crystalline regions of the target makes it possible to connect the final distributions of the components in the resolidified targets to the history of the laser-induced melting process, thus allowing for experimental verification of the computational predictions. (C) 2009 Elsevier B. V. All rights reserved.
Baggage handling on airports
(2008)
Characterization of a miniaturized unimorph deformable mirror for high power cw-solid state lasers
(2012)
We have developed a new type of unimorph deformable mirror for real-time intra-cavity phase control of high power cw-lasers. The approach is innovative in its combination of super-polished and pre-coated highly reflective substrates, the miniaturization of the unimorph principle, and the integration of a monolithic tip/tilt functionality. Despite the small optical aperture of only 9 mm diameter, the mirror is able to produce a stroke of several microns for low order Zernike modes, paired with a residual static root-mean-square aberration of less than 0.04 µm. In this paper, the characteristics of the mirror such as the influence functions, the dynamic behavior, and the power handling capability are reported. The mirror was subjected to a maximum of 490 W of laser-light at a wavelength of 1030 nm. Due to the high reflectivity of over 99.998 percent the mirror is able to withstand intensities up to 1.5 MW/cm2.
In order to avoid optical damage and non-linear effects, high-power, high-energy lasers of the petawatt class like PHELIX (petawatt high-energy laser for heavy-ion experiments) use large-aperture optics. Usually, chromatic aberration associated with these optical elements is neglected. By means of numerical simulations, we show how the chromatic aberration affects the focal intensity pattern. In particular, we make quantitative predictions of how chromatic aberration decreases the focused peak intensity. Furthermore, we prove the feasibility of a new interferometer that measures the temporal pulse front distortions which arise from expansion telescopes. We also propose a scheme that pre-compensates these distortions.
We summarise the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with the European Space Agency (ESA) and national space and research funding agencies.
This study presents a comprehensive evaluation of force sensors manufactured through conventional CNC machining, laser powder bed fusion (LPBF), and material extrusion (MEX) 3D printing methods. The study utilized a combination of finite element method (FEM) simulations, functional testing, durability assessments, and ultimate strength testing in order to assess the viability of additive manufacturing for sensing technology applications. The FEM simulations provided a preliminary framework for predictive analysis, closely aligning with experimental outcomes for LPBF and conventionally manufactured sensors. Nevertheless, discrepancies were observed in the performance of MEX-printed sensors during ultimate strength testing, necessitating the implementation of more comprehensive modeling approaches that take into account the distinctive material characteristics and failure mechanisms. Functional testing confirmed the operational capability of all sensors, thereby demonstrating their suitability for the intended application. Moreover, all sensors exhibited resilience during 50,000 cycles of cyclic testing, indicating reliability, durability, and satisfactory fatigue life performance. Notably, sensors produced via LPBF exhibited a significant increase in strength, nearly three times that of conventionally manufactured sensors. These findings suggest the potential for innovative sensor design and the expansion of their use into higher-loaded applications. Overall, while both LPBF and conventional methods demonstrated reliability and closely matched simulation predictions, further research is necessary to refine modeling approaches for MEX-printed sensors and fully unlock their potential in sensing technology applications. These findings indicate that additive manufacturing of metals may be a viable alternative for the fabrication of biomedical sensors.
Additive manufacturing (AM) has continuously grown in recent decades. Enhanced quality, further development of technology, and fall in prices make AM applicable and capable for various industrial applications, also for the manufacture of medical devices. 3D printing offers the possibility for an unprecedented adaptation to the anatomy of each patient, generating medical devices on a case-by-case basis. In many jurisdictions, custom-made devices qualify for an exemption to pre-market approval standards. This regulation is called into question by new technologies, like AM. Therefore, this article compares the current regulatory requirements for custom-made devices in Europe, the United States, and Australia and discusses the impact on 3D printed devices. It concludes that not all jurisdictions have yet adjusted their regulatory framework for custom-made devices to technological advances. Remaining uncertainties must be eliminated in order to help manufacturers comply with the regulatory requirements, emphasizing key aspects of AM.