The annual wastewater flow that is treated by public
wastewater treatment plants in Germany amounts
to approx. 10 ∗ 10^9 m3/a and forms an ”artificial” hydropower
potential that can be used for energy generation
or recovery. In the context of this paper, energy
recovery in the outlet of wastewater treatment plants
is examined using the specific example of the water
wheel at the Warendorf central wastewater treatment
plant. The ”artificial” hydropower potential can be
roughly estimated at up to 20 to 105 GWh/a , whereby
this is largely dependent on the hydraulic gradient.
The strong variance results, among other things, from
the findings of the water wheel operation in Warendorf.
The decisive aspect here is the differential factor,
which describes the deviation between the theoretical
and actual energy yield of the water wheel. The
factor includes maintenance work, downtimes and insufficient
inflows, which are associated with a loss of
output. In the case study, the annual energy recovery
amounts to approx. 2 % of the annual electricity consumption
of the wastewater treatment plant and can
be estimated to 23,500 kWh (2022). In the context
of the economic analysis, it can be seen that despite
the ”low” yield, economic operation is possible if the
system is viewed as a long-term investment - payback
period of the example is approx. 14,5 years. The
27-year operation (1996 - 2023) of the water wheel
at the Warendorf central wastewater treatment plant
confirms this and important findings on successful
practical operation can be shown in the context of
this paper.
Mechanical ventilation of buildings is generally based on steadily operating systems. This field is well known and established. But, an approach based on time-varied supply flow rates might improve indoor air quality, comfort, and energy consumption. Typical time-scales of the variation are in the order of seconds or minutes. Until now, the effects of unsteady ventilation scenarios are not fully described and so, reliable dimensioning rules are missing. Hence, with a better understanding of the flow in unsteady ventilation, systems can be calculated and optimised. To understand the effective mechanisms and derive functional relations between the flow field and variation parameters, full-field optical flow measurements are executed with a particle image velocimetry (PIV) system. Experiments are conducted under isothermal conditions in water in a small-scale room model (1.00 m × 0.67 m × 0.46 m) with two swirl ceiling diffusers, Reynolds-scaling assures similarity. In a series of experiments, the effects of different unsteady ventilation strategies on the flow fields are investigated and compared to steady conditions with the same mean exchange rate. Mean exchange rates, signal types, periods, and amplitudes are varied. Time-averaged normalised velocity fields already indicate notable differences between steady and unsteady cases especially for lower exchange rates: the distribution is more homogeneous in unsteady scenarios compared to steady conditions, and low-velocity areas are reduced while the mean velocity of the room increases. So, unsteady ventilation might be beneficial in terms of improved ventilation and energy savings in partial-load operation. Fast Fourier Transformation (FFT) analyses of the mean velocity for each field over the whole series detect the main frequency of the volume flow variation. By dividing the velocity field into smaller areas, this main frequency is still detected especially in the upper part of the room, but side frequencies play a role in the room as well.
The first oscillating water column was invented in 1940. In the past decades the need of wave energy systems has significantly increased. This article quickly describes the Wells turbine and possibilities to enhance its performance and should answer the question: what are the design parameters that can be optimized?
Furthermore it gives a small outlook about the history of oscillating Water Columns.
The Spreadsheet Energy System Model Generator (SESMG) is a tool for modeling and optimizing energy systems with a focus on urban systems. The SESMG is easily accessible as it comes with a browser-based graphical user interface, spreadsheets to provide data entry, and detailed documentation on how to use it. Programming skills are not required for the installation or application of the tool. The SESMG includes advanced modeling features such as the application of the multi-energy system (MES) approach, multi-objective optimization, model-based methods for reducing computational requirements, and automated conceptualization and result processing of urban energy systems with high spatial resolution. Due to its accessibility and the applied modeling methods, urban energy systems can be modeled and optimized with comparatively low effort.
In Germany, the current sectoral urban planning often leads to inefficient use of resources, partly because municipalities lack integrated planning instruments and argumentation strength toward politics, investors, or citizens. The paper develops the ResourcePlan as (i) legal and (ii) a planning instrument to support the efficient use of resources in urban neighborhoods. The integrative, multi-methodological approach addresses the use of natural resources in the building and infrastructural sectors of (i) water (storm- and wastewater) management, (ii) construction and maintenance of buildings and infrastructure, (iii) urban energy system planning, and (iv) land-use planning. First, the development as legal instrument is carried out, providing (i) premises for integrating resource protection at all legal levels and (ii) options for implementing the ResourcePlan within German municipal structures. Second, the evaluation framework for resource efficiency of the urban neighborhoods is set up for usage as a planning instrument. The framework provides a two-stage process that runs through the phases of setting up and implementing the ResourcePlan. (Eco)system services are evaluated as well as life cycle assessment and economic aspects. As a legal instrument, the ResourcePlan integrates resource protection into municipal planning and decision-making processes. The multi-methodological evaluation framework helps to assess inter-disciplinary resource efficiency, supports the spatial identification of synergies and conflicting goals, and contributes to transparent, resource-optimized planning decisions.
Diese Arbeit befasst sich mit Kostentrends in Zusammenhang mit technologischem Lernen von Windenergie an Land in den USA, in Deutschland und weltweit. Ziel dieser Arbeit ist es, eine Lernkurve für Windenergie an Land zu bestimmen. Dafür wurden Daten zu Stromgestehungskosten (LCOE) und Kosten für die Installation (COP) von Windenergieanlagen (WEA) im Zeitraum von 1983 bis einschließlich 2020 gesammelt, grafisch dargestellt und weitergehend ausgewertet. Die grafische Darstellung der Datenlage verdeutlicht die zeitliche Entwicklung der Technologie. Zur Beschreibung dieser Lernkurven wurden die Progress Ratio (PR) und Learning Rate (LR) in fünf unterschiedlichen Modellen bestimmt. Anhand derer sich in Kombination mit der zukünftig installierten Leistung von WEA eine Prognose über zukünftige Kosten ableiten lässt. Die ermittelten LR bewegen sich zwischen 13 % und 28 %, woraus sich LCOE im Jahr 2030 zwischen 44,03 US$/MWh und 61 US$/MWh ergeben.
Wind turbine structures take a major role in the
modern conversion to renewable energy sources and
contribute to the creation of a greener world. In recent
years, the development and installation of wind
turbines have seen rapid growth. However, with the
increasing capacity and size of wind farms worldwide,
there are growing concerns about the safety and reliability
of these installations. Therefore, structural
health monitoring and the detection of damage to
wind turbines have gained considerable importance in
research. Wind turbine blades are particularly susceptible
to various types of damage due to environmental
influences. This article provides an overview of signal
responses, sensors used and non-destructive testing
techniques in the field of damage detection on wind
turbine blades. The intention of the article is to give
an insight into the possibilities of structural health
monitoring and at the same time to point out unsolved
problems in this field.
Floating offshore wind (FOW) holds the key to 80 % of the total offshore wind resources, located in waters of 60 m and deeper in European seas, where traditional bottom-fixed offshore wind (BFOW) is not economically attractive.
Many problems affecting floating offshore wind turbines (FOWT) were quickly overcome based on previous experience with floating oil rigs and bottom-fixed offshore wind. However, this technology is still young and there are still many challenges to overcome.
This paper shows that electrical failures are amongst the most significant errors of FOWT. The most common cause was corrosion. It is also stated that the control system is most often affected, and that the Generator is frequently involved. Material corrosion is also the key factor when it comes to the most common overall reason for failures.
A particular attention must be paid to mooring line fracture. Mooring lines are especially vulnerable to extreme sea conditions and the resulting fatigue, corrosion, impact damage, and further risks.
It must be stated that the primary challenge is that of economics. Over time technological costs will decline making FOW more competitive and hence attractive for greater depth.