Faculty
We present a novel pump concept that should lead to single-frequency operation of thin-disk lasers without the need for etalons or other spectral filters. The single-frequency operation is due to matching the standing wave pattern of partially coherent pump light to the standing wave pattern of the laser light inside the disk. The output power and the optical efficiency of our novel pump concept are compared with conventional pumping. The feasibility of our pump concept was shown in previous experiments.
We have developed, manufactured and tested a unimorph deformable mirror for space applications based on piezoelectric actuation. The mirror was designed for the correction of low-order Zernike modes with a stroke of several tens of micrometers over a clear aperture of 50 mm. It was successfully tested in thermal vacuum, underwent lifetime tests, and was exposed to random vibrations, sinusoidal vibrations, and to ionizing radiation. We report on design considerations, manufacturing of the mirror, and present the test results. Furthermore, we discuss critical design parameters, and how our mirror could be adapted to serve recently proposed space telescopes such as HDST and TALC.
Active optics is an enabling technology for future large space telescopes. Image-based wavefront control uses an image-sharpness metric to evaluate the optical performance. A control algorithm iteratively adapts a corrective element to maximize this metric, without reconstructing the wavefront. We numerically study a sharpness metric in the space of Zernike modes, and reveal that for large aberrations the Zernike modes are not orthogonal with respect to this metric. The findings are experimentally verified by using a unimorph deformable mirror as
corrective element. We discuss the implications for the correction process and the design of control algorithms.
This paper presents the results of the technology development project “Enabling Technologies for Piezo-Based Deformable Mirrors in Active Optics Correction Chains” conducted by OHB System AG together with its partner Münster University of Applied Sciences (MUAS). The project was funded by ESA within their General Support Technology Programme
(GSTP).
We address in this paper mainly the definition, flow-down and verification of the requirements for the Deformable Mirror (DM). The requirements were derived from a set of real space mission applications. The deformation of the mirror is performed by piezo-ceramic actuators in an unimorph configuration. The finally developed DM is able produce Zernike modes with a stroke of several tens of µm over a clear optical aperture of 50 mm in diameter. It underwent successfully a full environmental qualification campaign including thermal cycling, shock- and vibration testing, as well as exposure to
proton and γ–ray radiation. Thermal and performance tests were performed in the temperature range from 100 K to 300 K.
Furthermore, the DM sustained all vibration (random 17.8 g RMS and sinus) and shock (300 g) testing. Thereby all criticalities which were identified a previous study have been overcome successfully.
A Technology Readiness Level (TRL) of 5 is reached, as the component has been validated in relevant environment. Based on the high level of maturity, this deformable mirror is now ready for the incorporation in future flight instruments. The achieved TRL of 5 is sufficient for the status of a PDR at payload level and gives thus a very good basis for all kinds of potential B2, C/D payload developments.
We present our latest results on a refined unimorph deformable mirror which was developed in the frame of the ESA GSTP activity ”Enabling Technologies for Piezo-Based Deformable Mirrors in Active Optics Correction Chains”. The identified baseline concept with the soft piezoceramic material PIC151 successfully sustained all vibration requirements (17.8 gRMS random and 20 g sine) and shock testing (300 g SRS). We cover the mirror design development which reduces the stress in the brittle piezo-ceramic by 90 % compared to the design from
a former GSTP activity. We briefly address the optical characterization of the deformable mirror, namely the achieved Zernike amplitudes as well as the unpowered surface deformation (1.7 µm) and active flattening (12.3 nmRMS). The mirror produces low-order Zernike modes with a stroke of several tens of micrometer over a correction aperture of 50 mm, which makes the mirror a versatile tool for space telescopes.
We have developed a new type of unimorph deformable mirror for the correction of low-order Zernike modes. The mirror features a clear aperture of 50 mm combined with large peak-to-valley amplitudes of up to 35 μm. Newly developed fabrication processes allow the use of prefabricated, coated, super-polished glass substrates. The mirror's unique features suggest the use in several astronomical applications like the compensation of atmospheric aberrations seen by laser beacons, low light astronomy, and the use in woofer-tweeter systems. Additionally, the design enables an efficient correction of the inevitable wave-front error imposed by the floppy structure of primary mirrors in future large space telescopes. We have modeled the mirror by using analytical as well as finite element models. We will present design, key features and manufacturing steps of the deformable mirror.
GSI Darmstadt currently builds a high-energy petawatt Nd:glass laser system, called PHELIX (Petawatt High-Energy Laser for Heavy-Ion Experiments). PHELIX will offer the world-wide unique combination of a high current, high-energy heavy-ion beam with an intense laser beam. Aberrations due to the beam transport and due to the amplification process limit the focusability and the intensity at the target. We have investigated the aberrations of the different amplification stages. The pre-amplifier stage consists of three rod-amplifiers which cause mainly defocus, but also a small part of coma and astigmatism. The main amplifier consists of five disk amplifiers with a clear aperture of 315 mm. These large disk-amplifiers cause pump-shot aberrations which occur instantly. After a shot, the disk amplifiers need a cooling time of several hours to relax to their initial state. This limits the repetition rate and causes long-term aberrations. We will present first measurements of the pump-shot and long-term aberrations caused by the pre- and the main amplifier in a single-pass configuration. In this context, we will present the adaptive optics system which is implemented in the PHELIX beam line and discuss its capability to compensate for the pump-shot and long-term aberrations.
Characterization of a miniaturized unimorph deformable mirror for high power cw-solid state lasers
(2012)
We have developed a new type of unimorph deformable mirror for real-time intra-cavity phase control of high power cw-lasers. The approach is innovative in its combination of super-polished and pre-coated highly reflective substrates, the miniaturization of the unimorph principle, and the integration of a monolithic tip/tilt functionality. Despite the small optical aperture of only 9 mm diameter, the mirror is able to produce a stroke of several microns for low order Zernike modes, paired with a residual static root-mean-square aberration of less than 0.04 µm. In this paper, the characteristics of the mirror such as the influence functions, the dynamic behavior, and the power handling capability are reported. The mirror was subjected to a maximum of 490 W of laser-light at a wavelength of 1030 nm. Due to the high reflectivity of over 99.998 percent the mirror is able to withstand intensities up to 1.5 MW/cm2.
Efficient quasi-three-level laser operation requires the generation of the highest possible pump rate from a given pump source. We derive the fundamental scaling laws for the pump rate and we extract optimization criteria for pump concepts from these laws. The analysis is then applied to the thin-disk laser. Based on the results, a novel pump concept for thin-disk lasers is proposed, which allows for several tens of pump beam passes and reduces the optical complexity of conventional pump concepts. Furthermore, the beam quality of the pump source is preserved almost completely, facilitating the highest possible pump rate.
The actuator pattern of an adaptive mirror determines the amplitudes and the fidelities of the mirror deformations that can be achieved. In this study, we analyze and compare different electrode patterns of piezoelectric unimorph deformable mirrors using a numerical finite element model. The analysis allows us to determine the optimum actuator pattern, and it is also applicable to bimorph mirrors. The model is verified by comparing its predictions with experimental results of our prototype of a novel unimorph deformable mirror.