Wie viel ist wenig? Untersuchung zur Quantifizierung physischer Inaktivität an Fahrerarbeitsplätzen
(2016)
We present our latest results on a refined unimorph deformable mirror which was developed in the frame of the ESA GSTP activity ”Enabling Technologies for Piezo-Based Deformable Mirrors in Active Optics Correction Chains”. The identified baseline concept with the soft piezoceramic material PIC151 successfully sustained all vibration requirements (17.8 gRMS random and 20 g sine) and shock testing (300 g SRS). We cover the mirror design development which reduces the stress in the brittle piezo-ceramic by 90 % compared to the design from
a former GSTP activity. We briefly address the optical characterization of the deformable mirror, namely the achieved Zernike amplitudes as well as the unpowered surface deformation (1.7 µm) and active flattening (12.3 nmRMS). The mirror produces low-order Zernike modes with a stroke of several tens of micrometer over a correction aperture of 50 mm, which makes the mirror a versatile tool for space telescopes.
Verloren im Ballungsraum Intensivstation - Kommunikation zwischen Mensch und Maschine im Krankenhaus
(2006)
Vergleichende Evaluation der ergonomischen Gestaltungsqualität von Gepäckförderbändern auf Flughäfen
(2007)
Usability: Unique Selling Point of Market Leaders, Basics for Safety and User´s Satisfaction
(2006)
Usability-Engineering - Eine Methodenübersicht zur anwendergerechten Gestaltung von Medizinprodukten
(2001)
Usability of Medical Devices
(2006)
Untersuchung zur Anwendungsqualität von menügesteuerten Applikationsgeräten zur Infusionstherapie
(2005)
Untersuchung des Einflusses von Augmented Reality auf die Beanspruchung eines Kardiotechnikers
(2019)
Universal short-time response and formation of correlations after quantum quenches, K. Morawetz
(2017)
We have developed, manufactured and tested a unimorph deformable mirror for space applications based on piezoelectric actuation. The mirror was designed for the correction of low-order Zernike modes with a stroke of several tens of micrometers over a clear aperture of 50 mm. It was successfully tested in thermal vacuum, underwent lifetime tests, and was exposed to random vibrations, sinusoidal vibrations, and to ionizing radiation. We report on design considerations, manufacturing of the mirror, and present the test results. Furthermore, we discuss critical design parameters, and how our mirror could be adapted to serve recently proposed space telescopes such as HDST and TALC.
Over the past 5 years we have developed a new type of unimorph deformable mirror. The main advantages of this mirror technology are · very low surface scattering due to the use of superpolished glass · excellent coatings, even suitable for high power lasers, can be applied · active diameter of the mirrors can be between 10 mm and 100 mm · large strokes can be achieved even for small mirror diameters · integrated monolithic tip/tilt functionality based on a spiral arm design We have modeled these mirrors by analytical models as well as by the finite element method. This allows us to quickly design new mirrors tailored to specific applications. One example is a mirror for laser applications that has a diameter of 10 mm and can achieve a stroke in defocus mode of 5 μm. The stroke for these mirrors scales as the square of the mirror diameter, meaning that we can achieve, for example, a stroke of 125 μm for a mirror of 50 mm diameter. We will present design criteria and tradeoffs for these mirrors. We characterize our mirrors by the maximum stroke they can deliver for various Zernike modes, under the boundary condition that the Zernike mode has to be created with a certain fidelity, usually defined by the Maréchal criterion.
We have developed and manufactured a unimorph deformable mirror for space telescopes based on piezoelectric actuation. The mirror features 44 actuators, has an aperture of 50 mm, and is designed to reproduce low-order Zernike modes with a stroke of several tens of µm. We assessed the space compliance by operating the mirror in thermal vacuum, and exposing it to random and sinusoidal vibrations, as well as to ionizing irradiation. Additionally, the operational life time and the laser power handling capability were tested. The mirror was successfully operated in thermal vacuum at 100 K. We report on the conducted tests and the methods used to evaluate the mirror´s performance, and discuss the compliance with the demanded requirements
Large space telescopes made of deployable and lightweight structures suffer from aberrations caused by thermal deformations, gravitational release, and alignment errors which occur during the deployment procedure. An active optics system would allow on-site correction of wave-front errors, and ease the requirements on thermal and mechanical stability of the optical train. In the course of a project funded by the European Space Agency we have developed and manufactured a unimorph deformable mirror based on piezoelectric actuation. The mirror is able to work in space environment and is designed to correct for large aberrations of low order with high surface fidelity. This paper discusses design, manufacturing and performance results of the deformable mirror.
Ultrakurzpuls Laserbearbeitung mit resonatorexterner Strahlformung durch deformierbare Spiegel
(2015)
Two-photon polymerization with diode lasers emitting ultrashort pulses with high repetition rate
(2020)
In this Letter, we investigate the resolution of two-photon polymerization (2PP) with an amplified mode-locked external cavity diode laser with adjustable pulse length and a high repetition rate. The experimental results are analyzed with a newly developed 2PP model. Even with low pulse peak intensity, the produced structural dimensions are comparable to those generated by traditional 2PP laser sources. Thus, we show that a compact monolithic picosecond laser diode without amplification and with a repetition rate in the GHz regime can also be applied for 2PP. These results show the high application potential of compact mode-locked diode lasers for low-cost and compact 2PP systems.
Transient time period
(2016)
The use of computational modeling and simulation (CMS) as a tool for gaining insight into the technical performance and safety of medical devices has emerged continuously over the past years. However, to rely on information and decisions derived from model predictions, it is essential to establish model credibility for the specific context of use. Limited regulatory requirements and lack of consensus on the level of verification and validation activities required result in rare use of CMS as a source of evidence in the medical device approval process. The American Society of Mechanical Engineers (ASME) developed a risk-informed framework to establish appropriate credibility requirements of a computational model: the ASME V&V 40?2018 standard. This paper aims to outline the concepts of this standard and to demonstrate its application using an example from the orthotics field. The necessary steps to establish model credibility for a custom?made 3D printed wrist hand orthosis (WHO) are presented. It is shown that the credibility requirements of each verification and validation activity depend on model risk by applying two different contexts of use to the same computational model.
Torsions- und Druckbelastung am Knick-Senkfuß mit und ohne sensomotorisch wirkender Fußorthese
(2018)
Consequences of the consistent exact solution of Einstein{Cartan equation on the time dependence of Hubble parameter are discussed. The torsion leads to a space and time-dependent expansion parameter which results into nontrivial windows of Hubble parameter between diverging behavior.
Only one window shows a period of decreasing followed by increasing time dependence. Provided a known cosmological constant and the present values of Hubble and deceleration parameter this
changing time can be given in the past as well as the ending time of the windows or universe. The comparison with the present experimental data allows to determine all parameters of the model.
Large-scale spatial periodic structures appear. From the metric with torsion outside matter, it is seen that torsion can feign dark matter.
Two different scenarios are usually invoked in the formation of femtosecond Laser-Induced Periodic Surface Structures (LIPSS), either “self-organization” mechanisms or a purely “plasmonic” approach. In this paper, a three-step model of formation of single-laser-shot LIPSS is summarized. It is based on the periodic perturbation of the electronic temperature followed by an amplification, for given spatial periods, of the modulation in the lattice temperature and a final possible relocation by hydrodynamic instabilities. An analytical theory of the evolution of the temperature inhomogeneities is reported and supported by numerical calculations on the examples of three different metals: Al, Au, and Mo. The criteria of the possibility of hydrodynamic instabilities are also discussed.