Physikingenieurwesen (PHY)
Refine
Year
Publication Type
- Article (395)
- Conference Proceeding (160)
- Part of a Book (146)
- Lecture (100)
- Book (20)
- Contribution to a Periodical (5)
- Participation in a Norm (DIN, RFC etc.) (2)
- Other (1)
- Part of Periodical (1)
- Report (1)
Language
- English (516)
- German (266)
- Multiple languages (48)
- French (1)
Keywords
Faculty
A numerical analysis of laser resonators with aberrations is presented. {T}he analysis shows that aberrations lead to large diffraction losses of laser resonators which are laid out to produce diffraction-limited beam quality. {S}tatic or dynamic compensation of the aberrations is possible and would yield much higher output power.
The spatially varying intensity in a standing wave resonator leads to spatial hole burning in the gain medium of a laser. The spatial hole burning changes the gain of different longitudinal modes and can thus determine the optical spectrum of the laser. We simulate this longitudinal mode competition in standing wave resonators of thin-disk lasers. The resulting optical spectra of the laser are compared to measured optical spectra. We examine two types of resonators: I-resonators and V-resonators with different angles of incidence. In V-resonators, the non-normal incidence of the laser beam on the disk lifts the degeneracy of the polarization. Experiments show that the slight gain advantage for the p-polarization does not lead to polarized emission. For both types of resonators, the measured spectra are in good agreement with the simulated ones. The simulations allow to study the influence of spectral intra-cavity losses on the optical spectrum of a thin-disk laser.
Large space telescopes made of deployable and lightweight structures suffer from aberrations caused by thermal deformations, gravitational release, and alignment errors which occur during the deployment procedure. An active optics system would allow on-site correction of wave-front errors, and ease the requirements on thermal and mechanical stability of the optical train. In the course of a project funded by the European Space Agency we have developed and manufactured a unimorph deformable mirror based on piezoelectric actuation. The mirror is able to work in space environment and is designed to correct for large aberrations of low order with high surface fidelity. This paper discusses design, manufacturing and performance results of the deformable mirror.
We report interferometric measurements of the temperature coefficient of the refractive index (dn=dT) and the coefficient of thermal expansion (a) of a praseodymium-doped yttrium lithium fluoride (Pr:YLF) crystal and of a fused silica reference sample. Our phase-resolved interferometric method yields a large number of data points and thus allows a precise measurement and a good error estimation. Furthermore, both dn=dT and a are obtained simultaneously from a single measurement which reduces errors that can occur in separate measurements. Over the temperature range from 20 °C to 80 °C, the value of dn=dT of Pr:YLF decreases from -5.2 x 10-6 /K to -6.2 x 10-6 /K for the ordinary refractive index and from -7.6 x 10-6 /K to -8.6 x 10-6 /K for the extraordinary refractive index. The coefficient of thermal expansion for the a-axis of Pr:YLF increases from 16.4 x 10-6 /K to 17.8 x 10-6 /K over the same temperature range.
Concepts for future large space telescopes require an active optics system to mitigate aberrations caused by thermal deformation and gravitational release. Such a system would allow on-site correction of wave-front errors and ease the requirements for thermal and gravitational stability of the optical train. In the course of the ESA project "Development of Adaptive Deformable Mirrors for Space Instruments" we have developed a unimorph deformable mirror designed to correct for low-order aberrations and dedicated to be used in space environment. We briefly report on design and manufacturing of the deformable mirror and present results from performance verifications and environmental testing.
We report on interferometric measurements of the thermo-optical aberrations of the laser medium of an Yb:YAG thin-disk laser in pumped and cw lasing conditions at several pump-power levels with a mean repeatability of 5 nm. These measurements build the basis for future intracavity compensation of the aberrations with our deformable mirror in order to improve the fundamental-mode efficiency.
Adaptive laser resonators with deformable MOEMS mirrors under closed-loop control are discussed and experimental results are presented. The requirements for deformable mirrors and for closed-loop control systems of these mirrors are analyzed. Several deformable mirrors have been characterized and the results are presented. Currently available membrane mirrors deform under laser load and need further development before they can be used for aberration correction of solid state lasers above some tens of Watts. Nevertheless, the results are encouraging and the requirements are within reach of currently available technology. Finally, we demonstrate an Nd.YVO4-laser with a closed-loop adaptive resonator and more than 6 W of output power. The closed-loop system was able to compensate artificially introduced aberrations from a phase plate.
In order to avoid optical damage and non-linear effects, high-power, high-energy lasers of the petawatt class like PHELIX (petawatt high-energy laser for heavy-ion experiments) use large-aperture optics. Usually, chromatic aberration associated with these optical elements is neglected. By means of numerical simulations, we show how the chromatic aberration affects the focal intensity pattern. In particular, we make quantitative predictions of how chromatic aberration decreases the focused peak intensity. Furthermore, we prove the feasibility of a new interferometer that measures the temporal pulse front distortions which arise from expansion telescopes. We also propose a scheme that pre-compensates these distortions.
GSI Darmstadt currently builds a high-energy petawatt Nd:glass laser system, called PHELIX (Petawatt High-Energy Laser for Heavy-Ion Experiments). PHELIX will offer the world-wide unique combination of a high current, high-energy heavy-ion beam with an intense laser beam. Aberrations due to the beam transport and due to the amplification process limit the focusability and the intensity at the target. We have investigated the aberrations of the different amplification stages. The pre-amplifier stage consists of three rod-amplifiers which cause mainly defocus, but also a small part of coma and astigmatism. The main amplifier consists of five disk amplifiers with a clear aperture of 315 mm. These large disk-amplifiers cause pump-shot aberrations which occur instantly. After a shot, the disk amplifiers need a cooling time of several hours to relax to their initial state. This limits the repetition rate and causes long-term aberrations. We will present first measurements of the pump-shot and long-term aberrations caused by the pre- and the main amplifier in a single-pass configuration. In this context, we will present the adaptive optics system which is implemented in the PHELIX beam line and discuss its capability to compensate for the pump-shot and long-term aberrations.