Physikingenieurwesen (PHY)
Refine
Year
Publication Type
- Article (20)
- Conference Proceeding (19)
- Book (1)
- Report (1)
Has Fulltext
- yes (41) (remove)
Keywords
- adaptive optics (3)
- deformable mirror (3)
- active optics (2)
- active optics, adaptive optics, sharpness metrics, aberration compensation, algorithm design (2)
- space optics (2)
- space telescopes (2)
- Active or adaptive optics (1)
- CMS (1)
- Deformable mirror, adaptive mirror, unimorph mirror, high-power laser (1)
- Gravitation, Hubble constant, Cosmology, Torsion (1)
Efficient quasi-three-level laser operation requires the generation of the highest possible pump rate from a given pump source. We derive the fundamental scaling laws for the pump rate and we extract optimization criteria for pump concepts from these laws. The analysis is then applied to the thin-disk laser. Based on the results, a novel pump concept for thin-disk lasers is proposed, which allows for several tens of pump beam passes and reduces the optical complexity of conventional pump concepts. Furthermore, the beam quality of the pump source is preserved almost completely, facilitating the highest possible pump rate.
We summarise the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with the European Space Agency (ESA) and national space and research funding agencies.
A numerical analysis of laser resonators with aberrations is presented. {T}he analysis shows that aberrations lead to large diffraction losses of laser resonators which are laid out to produce diffraction-limited beam quality. {S}tatic or dynamic compensation of the aberrations is possible and would yield much higher output power.
Objectives: In recent years, the European Union has revised its regulatory framework for medical devices, primarily to improve patient safety and public health. The Medical Device Regulation (MDR) is fully applicable since May 2021, strengthening the requirements for all stakeholders. As a result, many companies are facing enormous challenges. The aim of this study was to assess the impact of the MDR on the orthopaedic aids industry.
Methods: Two surveys were conducted: one shortly before the MDR became applicable (146 respondents) and a second survey almost two years later (233 respondents).
Results: Both surveys revealed that all businesses in the orthopaedic aids sector, regardless of size, have difficulty implementing the MDR. Key challenges include additional workload for technical documentation, increased resource expenditure and cost, and lack of clarity regarding the new requirements. Many companies are downsizing their product portfolio, resulting in potential supply shortages and a loss of competitive advantage and innovation for the medical device industry in Europe.
Conclusions: The full extent of the MDR’s impact on clinical practice is still unclear. However, many companies lack the necessary resources. The MDR can potentially be a bottleneck in the availability of medical devices.
The use of computational modeling and simulation (CMS) as a tool for gaining insight into the technical performance and safety of medical devices has emerged continuously over the past years. However, to rely on information and decisions derived from model predictions, it is essential to establish model credibility for the specific context of use. Limited regulatory requirements and lack of consensus on the level of verification and validation activities required result in rare use of CMS as a source of evidence in the medical device approval process. The American Society of Mechanical Engineers (ASME) developed a risk-informed framework to establish appropriate credibility requirements of a computational model: the ASME V&V 40?2018 standard. This paper aims to outline the concepts of this standard and to demonstrate its application using an example from the orthotics field. The necessary steps to establish model credibility for a custom?made 3D printed wrist hand orthosis (WHO) are presented. It is shown that the credibility requirements of each verification and validation activity depend on model risk by applying two different contexts of use to the same computational model.
Further space exploration in the far-infrared (FIR) requires larger apertures in order to improve the spatial resolution of captured images. To this purpose, the Thinned Aperture Light Collector (TALC) concept of a deployable annular telescope has been recently developed at CEA, which offers novel perspectives for FIR space missions. The consortium ELICSIR consortium of European institutes and companies has been created to improve the technological readiness level (TRL) of its key systems and components.
This paper presents the results of the technology development project “Enabling Technologies for Piezo-Based Deformable Mirrors in Active Optics Correction Chains” conducted by OHB System AG together with its partner Münster University of Applied Sciences (MUAS). The project was funded by ESA within their General Support Technology Programme
(GSTP).
We address in this paper mainly the definition, flow-down and verification of the requirements for the Deformable Mirror (DM). The requirements were derived from a set of real space mission applications. The deformation of the mirror is performed by piezo-ceramic actuators in an unimorph configuration. The finally developed DM is able produce Zernike modes with a stroke of several tens of µm over a clear optical aperture of 50 mm in diameter. It underwent successfully a full environmental qualification campaign including thermal cycling, shock- and vibration testing, as well as exposure to
proton and γ–ray radiation. Thermal and performance tests were performed in the temperature range from 100 K to 300 K.
Furthermore, the DM sustained all vibration (random 17.8 g RMS and sinus) and shock (300 g) testing. Thereby all criticalities which were identified a previous study have been overcome successfully.
A Technology Readiness Level (TRL) of 5 is reached, as the component has been validated in relevant environment. Based on the high level of maturity, this deformable mirror is now ready for the incorporation in future flight instruments. The achieved TRL of 5 is sufficient for the status of a PDR at payload level and gives thus a very good basis for all kinds of potential B2, C/D payload developments.
In order to avoid optical damage and non-linear effects, high-power, high-energy lasers of the petawatt class like PHELIX (petawatt high-energy laser for heavy-ion experiments) use large-aperture optics. Usually, chromatic aberration associated with these optical elements is neglected. By means of numerical simulations, we show how the chromatic aberration affects the focal intensity pattern. In particular, we make quantitative predictions of how chromatic aberration decreases the focused peak intensity. Furthermore, we prove the feasibility of a new interferometer that measures the temporal pulse front distortions which arise from expansion telescopes. We also propose a scheme that pre-compensates these distortions.
GSI Darmstadt currently builds a high-energy petawatt Nd:glass laser system, called PHELIX (Petawatt High-Energy Laser for Heavy-Ion Experiments). PHELIX will offer the world-wide unique combination of a high current, high-energy heavy-ion beam with an intense laser beam. Aberrations due to the beam transport and due to the amplification process limit the focusability and the intensity at the target. We have investigated the aberrations of the different amplification stages. The pre-amplifier stage consists of three rod-amplifiers which cause mainly defocus, but also a small part of coma and astigmatism. The main amplifier consists of five disk amplifiers with a clear aperture of 315 mm. These large disk-amplifiers cause pump-shot aberrations which occur instantly. After a shot, the disk amplifiers need a cooling time of several hours to relax to their initial state. This limits the repetition rate and causes long-term aberrations. We will present first measurements of the pump-shot and long-term aberrations caused by the pre- and the main amplifier in a single-pass configuration. In this context, we will present the adaptive optics system which is implemented in the PHELIX beam line and discuss its capability to compensate for the pump-shot and long-term aberrations.