TY - CHAP A1 - Durand, G. A1 - Amiaux, J. A1 - Sauvage, M. A1 - Austin, J. A1 - Chesne, S. A1 - Collette, C. A1 - Helgouashl, S. A1 - Pareschi, J. A1 - Penfornis, Y. A1 - Valsecchi, G. A1 - Wittrock, U. T1 - TALC a far-infrared 20m space telescope and the ELICSIR consortium to reach TRL 3 T2 - Proceedings of the 37th ESA Antenna Workshop, Noordwijk, Netherlands N2 - Further space exploration in the far-infrared (FIR) requires larger apertures in order to improve the spatial resolution of captured images. To this purpose, the Thinned Aperture Light Collector (TALC) concept of a deployable annular telescope has been recently developed at CEA, which offers novel perspectives for FIR space missions. The consortium ELICSIR consortium of European institutes and companies has been created to improve the technological readiness level (TRL) of its key systems and components. Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:836-opus-9253 UR - http://esaconferencebureau.com/2016-events/16c18/introduction ER - TY - CHAP A1 - Estevez, F. A1 - Rebel, G. A1 - González, J. A1 - Palomares, J.M. A1 - Glösekötter, P. T1 - Body energy harvesting for WSN. State of art and examples T2 - Proceedings JCE 09/2013 N2 - Body energy harvesting for WSN. State of art and examples Y1 - 2013 U6 - http://dx.doi.org/10.25974/fhms-707 PB - JCE ER - TY - CHAP A1 - Falter, Bernhard T1 - LINING STABILITY: AN ANALYSIS OF DAMAGED SEWERS T2 - North American Society for Trenchless Technologies (NASTT), NO-DIG 2004, New Orleans, Louisiana, March 22-24, 2004 N2 - With the assessment of sewers and drains generally recognised criteria such as tightness, stability, hydraulic capability and efficiency are valid. For the assessment of the stability, however, there are often uncertainties. In this connection the ATV-DVWK Advisory Leaflet ATV M 127-2 represents a practical development of the system of rules and standards for the stability of earth-bedded pipelines that is called upon in the case of dimensioning for rehabilitation procedures. Nevertheless, further assumptions about the pipe-soil system are necessary which often are based on individual appraisals and experiences of the designer. To that end, in the years 1999 to the beginning of 2002, extensive experiments and theoretical investigations were carried out at the Universities of Bremen and Muenster as well as at the Bremen hanseWasser GmbH in order to assess more reliably the load-carrying capacity in particular of damaged host pipes in the ground. The research was supported by the Federal Ministry for Education and Research (BMB+F) under the short title ASSUR. The paper gives a view of the essential contents of the research; further information can be taken from the final report to ASSUR. N2 - Bei der Beurteilung von Abwasserkanälen und -leitungen gelten allgemein anerkannte Kriterien wie Dichtheit, Standsicherheit, hydraulische Leistungsfähigkeit und Wirtschaftlichkeit. Zur Beurteilung der Standsicherheit sind jedoch häufig Unsicherheiten anzutreffen. In diesem Zusammenhang stellt das Merkblatt M 127-2 der ATV eine praxisorientierte Weiterentwicklung des Regelwerks zur Standsicherheit von erdgebetteten Rohrleitungen dar, das bei Dimensionierungen für grabenlose Sanierungsverfahren hinzugezogen wird. Dennoch sind weiterhin Annahmen zum Rohr-Bodensystem zu treffen, die wiederum häufig auf individuellen Einschätzungen und Erfahrungen des Planers beruhen. Hierzu wurden in den Jahren 1999 bis Anfang 2002 von den Hochschulen Bremen und Münster sowie der hanseWasser Bremen GmbH umfangreiche Versuche und theoretische Untersuchungen durchgeführt, um die Tragfähigkeit insbesondere von geschädigten Alt-rohren im Boden sicherer zu beurteilen. Die Arbeiten wurden vom Bundesministerium für Bildung und Forschung (BMB+F) unter dem Kurztitel ASSUR gefördert. Der Vortrag gibt einen Überblick über die wesentlichen Inhalte des Vorhabens, Näheres kann dem Abschlussbericht zu ASSUR entnommen werden. KW - Liner KW - Altrohrschäden KW - Altrohrzustand III KW - Mauerwerkssammler KW - gerissene Rohre KW - Druckzone KW - Bodenspannungen KW - Belastungsversuche KW - Belastungsfahrzeug KW - Liner KW - damaged pipes KW - Host Pipe Stage III KW - masonry sewer KW - broken pipe KW - pressure zone KW - soil stresses KW - loading test KW - load vehicle Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:836-opus-190 PB - North American Society for Trenchless Technology ER - TY - CHAP A1 - Falter, Bernhard T1 - New developments in liner design due to ATV-M 127-2 T2 - North-American Society for Trenchless Technology 2008 No-Dig Conference & Exhibition, Dallas, Texas, April 27 - Mai 2, 2008, Paper C-1-03-1 N2 - The German Code ATV-M 127-2 published in 2000 for the design of linings to rehabilitate sewers has proved itself a helpful guideline to find the optimum wall thickness of any liner material, e.g. CIPP or stainless steel sleeves. Many rehabilitation projects in different European countries have been performed successfully using this code. The code differentiates between three host pipe states: State I for untight sewers without cracks, state II for sewers with longitudinal cracks but a stable soil pipe system and state III for cracked pipes with larger deformations and considerable risk to collapse in the near future. State II sewers but installed close to the traffic surface must be calculated as a state III situation too. According to the code stress, deformation and stability tests are necessary. For many practical cases charts with stress factors and imperfection reductions allow to design without a computer. Numerous theoretical and experimental papers are available which mainly deal with circular linings. An evaluation of design codes carried out by experts of different countries shows a fairly good coincidence of the required wall thicknesses, but the assessment of pipeline damages by engineers is sometimes resulting in quite different assumptions necessary for the design input parameters. The paper reports about the progress in liner design since the 1st edition of the code. Additional clauses have to be introduced into the 2nd edition for non circular geometries (e.g. for hood and rectangular profile), imperfections describing practical and theoretical situations and new applications (e.g. railway crossings). International discussion can be useful to find safe and resources saving constructions. N2 - Das im Jahr 2000 veröffentlichte deutsche Regelwerk ATV-M 127-2 zur Dimensionierung von Linern für Abwasserkanäle erweist sich als gute Richtlinie zur Ermittlung der optimalen Wanddicken von Linern aus beliebigem Material, wie z. B. faserverstärkte Kunststoffe oder Manschetten aus nicht rostendem Stahl. Viele Sanierungsprojekte in verschiedenen europäischen Ländern wurden mit Hilfe dieser Richtlinie erfolgreich durchgeführt. Die Richtlinie differenziert zwischen drei Altrohrzuständen: Der erste Zustand gilt für ein Abwasserrohr ohne Risse, der zweite Zustand für Rohre mit Längsrissen, aber einem stabilen Rohr-Boden-System und der dritte Zustand für das gerissene Rohr mit größeren Verformungen und hohem Risiko des Versagens in naher Zukunft. Abwasserrohre im Zustand II, die in der Nähe einer Verkehrsfläche liegen, müssen genauso behandelt werden wie Abwasserrohre im Zustand III. Gemäß der Richtlinie sind Spannungs-, Verformungs-, und Stabilitätsnachweise erforderlich. Für viele praktische Fälle wurden Diagramme mit Spannungsfaktoren und Abminderungsbeiwerten entwickelt, die eine Dimensionierung ohne Computer ermöglichen. Es wurde eine Vielzahl von theoretischen und experimentellen Arbeiten veröffentlicht, die sich hauptsächlich auf kreisförmige Liner konzentrieren. Eine Auswertung von Berechnungsverfahren ergab, dass eine relativ gute Übereinstimmung der Ergebnisse von Experten aus verschiedenen Ländern bezüglich der erforderlichen Wanddicken vorliegt, die Ingenieure jedoch mitunter ganz unterschiedliche Annahmen für die Rohrverformungen treffen. Es wird über Fortschritte in der Linerdimensionierung seit der ersten Ausgabe des Regelwerks im Jahr 2000 berichtet. In der zweiten Auflage werden für nicht kreisförmige Querschnitte zusätzliche Beiwerte eingeführt, z. B. für Ei- und Rechteckprofile. Wichtige zukünftige Anwendungsbereiche sind z. B. Eisenbahnkreuzungen. Eine internationale Diskussion ist nützlich, um sichere und wirtschaftliche Konstruktionen zu finden. T2 - Neue Entwicklungen in der Linerberechnung nach ATV-M 127-2 Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:836-opus-687 PB - North-American Society for Trenchless Technology ER - TY - CHAP A1 - Falter, Bernhard A1 - Hildebrand, Sonja A1 - Wolters, Martin T1 - Designing Liners for fully deteriorated sewers T2 - The North American Society (NASTT) and the International Society for Trenchless Technology (ISTT): International No-Dig Show 2009, Paper D-3-01 N2 - In the German design code ATV-M 127-2, three host pipe states are differentiated: State I for leaky sewers without cracks, state II for sewers with longitudinal cracks but a stable soil pipe system, and state III for cracked pipes with larger deformations and considerable risk of collapse in the near future. State II sewers that are close to the traffic surface must be calculated as a state III situation. On the other hand, the US Standard ASTM F 1216 defines two states: structurally safe and fully deteriorated sewers. This paper examines the common aspects and differences between the two codes. A simple non-linear numerical approach is presented to evaluate the actual safety of the host pipe-soil system based on the following parameters: 1. the pipe material (e. g. age, corrosion depth, state of the contact zones), 2. the measured or estimated pipe deformations, 3. the soil group, stiffness, and possible voids occurring next to the springlines of the pipe, 4. the loading to be applied on the deteriorated pipe-soil system. Using stability and ultimate stress criteria, the safety of the system can be defined in a rational way. Missing parameters have to be introduced into the algorithm conservatively. Case studies are presented to demonstrate safe estimations for the host pipe state. The consequences on the required wall thickness of a lining and the application of non-circular linings are shown. The wall thicknesses resulting from a design for the fully deteriorated state as defined by the design codes in both the USA and Germany are compared and discussed. KW - Verkehrslast KW - Druckzonen KW - Liner KW - Kanal KW - fully deteriorated gravity pipe KW - sewer KW - pressure zones KW - traffic load KW - liner Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:836-opus-2372 PB - The North American Society (NASTT) and the International Society for Trenchless Technology (ISTT) ER - TY - CHAP A1 - Gellenbeck, Klaus T1 - Trends of changes in waste management and possible optimizations within the waste collection process T2 - Zbornik 3. Problemske Konference Komunalnega Gospodarstva N2 - 1. General waste management in Europe 2. Optimization process of disposal logistics a. Technologies (collection systems, vehicles etc.) b. Benchmarking c. Optimization 3. The future and sustainability of waste management KW - Abfallmanagement KW - Abfall KW - waste management KW - waste collection Y1 - 2013 U6 - http://dx.doi.org/10.25974/fhms-705 PB - GZS CY - Ljubljana ER - TY - CHAP A1 - Gellenbeck, Klaus A1 - Riemenschneider, Frank A1 - Bernhold, Torben T1 - 11. Münsteraner Facility Management Tag N2 - Mittlerweile eine feste Institution und im Terminkalender vieler FM und CREM Verantwortlichen fixiert: Der Münsteraner Facility Management Tag. Seit nunmehr 10 Jahren kommen Interessierte und Freunde der FM-Branche nach Münster, um gemeinsam über Entwicklungen und Trends der Branche zu diskutieren. Der Münsteraner Facility Management Tag verfolgt dabei folgende Schwerpunkte: Darstellung praxisnaher Lösungsansätze Praxisorientierte Wissensvermittlung Stärkung des Transfers zwischen Theorie und Praxis unter dem Motto "Wissenschaft.Praktisch.Machen" Erfahrungsaustausch und best-practice Y1 - 2013 ER - TY - CHAP A1 - Gellenbeck, Klaus A1 - Schulte, Nico A1 - Nelles, Michael T1 - Entwicklung von prozessorientierten Qualitätsprüfungen für die haushaltsnahe Abfall- und Wertstoffsammlung T2 - Tagungsband 15. Dialog Abfallwirtschaft Mecklenburg-Vorpommern N2 - Die aktuelle Standardisierung und Normung von Dienstleistungen in der Abfall- und Wertstoffsammlung unter Angebe konkreter Service Levels verdeutlicht die Notwendigkeit von Qualitätsprüfungen als Bestandteil des Qualitätsmanagements in diesem Bereich. Die aktuelle Untersuchung hat das Ziel, praxisrelevante Qualitätsmerkmale abzuleiten, in der Praxis messbare Indikatoren zu identifizieren und eine Methodik zur Durchführung der Qualitätsprüfungen zu entwickeln. Y1 - 2012 SN - 978-3-940364-26-5 U6 - http://dx.doi.org/10.25974/fhms-686 SP - 1 EP - 18 PB - Wiss.-Verl. CY - Puttbus ER - TY - CHAP A1 - Heuck, Hans-Martin A1 - Wittrock, Ulrich A1 - Fils, Jérome A1 - Borneis, Stefan A1 - Witte, Klaus A1 - Eisenbart, Udo A1 - Javorkova, Dasa A1 - Bagnoud, Vincent A1 - Götte, Stefan A1 - Tauschwitz, Andreas A1 - Onkels, Eckehard T1 - Adaptive optics at the PHELIX laser T2 - Adaptive Optics for Laser Systems and Other Applications, Proc. SPIE N2 - GSI Darmstadt currently builds a high-energy petawatt Nd:glass laser system, called PHELIX (Petawatt High-Energy Laser for Heavy-Ion Experiments). PHELIX will offer the world-wide unique combination of a high current, high-energy heavy-ion beam with an intense laser beam. Aberrations due to the beam transport and due to the amplification process limit the focusability and the intensity at the target. We have investigated the aberrations of the different amplification stages. The pre-amplifier stage consists of three rod-amplifiers which cause mainly defocus, but also a small part of coma and astigmatism. The main amplifier consists of five disk amplifiers with a clear aperture of 315 mm. These large disk-amplifiers cause pump-shot aberrations which occur instantly. After a shot, the disk amplifiers need a cooling time of several hours to relax to their initial state. This limits the repetition rate and causes long-term aberrations. We will present first measurements of the pump-shot and long-term aberrations caused by the pre- and the main amplifier in a single-pass configuration. In this context, we will present the adaptive optics system which is implemented in the PHELIX beam line and discuss its capability to compensate for the pump-shot and long-term aberrations. Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:836-opus-6215 VL - 6584 SP - 658402 PB - SPIE ER - TY - CHAP A1 - Holzapfel, Dominik A1 - Heider, Thomas A1 - Kriete, Berndt A1 - Wallraven, Guido A1 - Ahlke, Ulrich A1 - Seidenstücker, Christina A1 - Richard, Daniel A1 - Thomsen, Jochen A1 - Höper, Jutta ED - Wetter, Christof ED - Brügging, E. T1 - Wärmewende im ländlichen Raum T2 - 9. Steinfurter Bioenergiefachtagung N2 - Die Hälfte des Endenergiebedarfs in Deutschland wird zur Deckung des Wärmebedarfs der Wirtschaft und der privaten Haushalte benötigt; überwiegend erzeugt durch Erdgas und Heizöl. Gerade die energetisch nur unzureichend sanierten Einfamilienhausbestände des ländlichen Raumes bergen ein hohes Potenzial für Energieeinsparungs- und Effizienzsstrategien, um zum einen den Klimaschutz zu fördern und zum anderen eine nachhaltige wirtschaftliche Entwicklung des ländlichen Raumes anzustoßen. Die 9. Steinfurter Bioenergiefachtagung zeigt Strategien und Maßnahmen auf, die zeigen, wie eine "Wärmewende im ländlichen Raum" aussehen kann, welche Chancen und Möglichkeiten sie bietet und warum eine "Wärmewende" strategisch unabdingbar für das Gelingen des Generationenprojektes "Energiewende" insgesamt ist. Die Veranstaltung zeichnet den Pfad von konzeptionellen Ideen über Beispiele aus der Praxis bis hin zu zukunftsweisenden technologischen Ansätzen: Wärmekataster Kreis Steinfurt KWK-Modellkommune Saerbeck Wege zum Bioenergiedorf - Praxisbeispiele Technische Voraussetzungen und Möglichkeiten für effiziente Wärmenetze im ländlichen Raum Finanzierungs- und Fördermodelle für eine gelungene Wärmewende KW - Bioenergiefachtagung KW - Wärmewende Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:836-opus-8541 ER -