TY - CONF A1 - Leutnant, Dominik A1 - Kleckers, Jonas A1 - Haberkamp, Jens A1 - Uhl, Mathias T1 - Assessing the Performance of Decentralised Stormwater Management Measures by means of Continuous Turbidity Measurement T2 - Novatech 2019 - 10th international conference on Urban Water – Strategies and solutions for sustainable management N2 - The in-situ performance of large decentralised stormwater treatment systems is investigated by means of continuous turbidity measurements. Turbidity measurements are used as a surrogate to continuously estimate Total Suspended Solid (TSS) concentrations. TSS event loads are calculated at the inlet and outlet of two stormwater treatment systems, which both are installed at the outlet of catchments with high pollution potential. The event-specific performance is defined as ratio between TSS loads of inflow and outflow. Based on measurement data obtained, the overall TSS load retention efficiency is about 32 %. Y1 - 2019 UR - https://www.hb.fh-muenster.de/opus4/frontdoor/index/index/docId/12123 UR - http://www.novatech.graie.org SP - 130 EP - 133 ER -